You can click on any word in the scrolling display and it is inserted into the appropriate log field. Click on a trace in the CW Skimmer waterfall, and the program displays the decoded text in a scrolling marquee just above the status bar. Integration also allows you to use CW Skimmer as a Morse decoder. KComm checks the whole log unless contest mode has been selected, in which case it checks only the entries for that contest. If the call has been worked before (contest duplicate) then it is colored gray. KComm checks this call against the log and sends a reply to Skimmer that allows it to color code a call if it is a new country or some other type of entity (prefix, zone).

When CW Skimmer integration is used, KComm receives a notification of every new DX call that CW Skimmer spots. This is not essential but avoids conflict if CW Skimmer and KComm both try to use the soundcard at the same time.
#MRP40 CW MORSE DECODER DRIVER#
Sound card driver - If you use any of KComm's internal soundcard options select MME. Some other CW Skimmer settings need to be set up a certain way:
#MRP40 CW MORSE DECODER SERIAL#
(It is possible that com0com could be used as an alternative serial port splitter, however I haven't tried it and the setup looks to be more complicated.) Then configure KComm and CW Skimmer to connect to the virtual serial port instead.


Use it to create a splitter in which the real serial port is the one connected to your transceiver. This is a freeware tool that lets you create various virtual devices.
#MRP40 CW MORSE DECODER INSTALL#
To allow both programs to have simultaneous access to the serial port to control your K2 or K3, you must install the Eterlogic Virtual Serial Port Emulator. It is not normally possible for two programs to access a serial port at the same time under Windows. To avoid false spots it is also recommended to use "Aggressive" call validation.ĬW Skimmer requires access to the serial port in order to set and get the frequency from the K2 or K3 - as does KComm. To avoid this, select "Do not send callsigns without CQ" on the Telnet tab. Note: CW Skimmer may spot the call of the station the one you are receiving is working.
#MRP40 CW MORSE DECODER FULL#
#MRP40 CW MORSE DECODER SOFTWARE#
The CW Software settings allow you to set up integration (or communication) between KComm and one of two Windows CW decoder programs, CW Skimmer and MRP40.